Updraft

Proof load of bolts, coarse thread

Thread designationPitch
[mm]
Effective sectional area
[mm2]
Proof load [N]

Notes

  • The table covers only the designations given in the source. A blank means that that property class is not specified for that size (property class 9.8 applies only up to 16 mm).
  • The proof load is the effective sectional area multiplied by the proof stress. The effective sectional area is calculated as given in JIS B 1082. Checked against the table in the source (JIS B 1051:2014, Table 5).
  • The values here are for room temperature. Mechanical properties change at high and low temperatures, so do not apply these values directly.
  • Sources: JIS B 1051, JIS B 0205-4, JIS B 1082
Bolts — Proof load — Proof load of bolts, coarse thread | Updraft - Mechanical Engineering Calculators